ASHRAE CLTD method — residential & commercial

Cooling Load Results
Save to project room:
kW
Tons of Refrig.
TR
BTU/hr
BTU/hr
Load Breakdown (detail)
Envelope
Occupants
Solar
Lighting
Equipment
Ventilation

Heating Load

Fabric + ventilation heat loss per ASHRAE / EN 12831

Heating Load Results
Save to project room:
kW
W per m²
W/m²
Delta T
°C
Heat Loss Breakdown (detail)
Walls
Roof
Floor
Windows
Ventilation

Duct Sizer

Equal friction method — ASHRAE HVAC Applications Handbook

Duct Sizing Results
Circular Diameter
Rect. Width × Height
mm × mm
Design Velocity
m/s
Friction Loss
Pa/m
Dynamic Pressure
Pa
Cross-Section Area

DuctSizer Pro

Full McQuay DesignTools-style solver — tick any 2 known values, solve for everything else

Fluid Density
1.2014 kg/m³
Fluid Viscosity
0.0643 kg/m·h
Specific Heat
1.0048 kJ/kg°C
Energy Factor
1.21 W/°C·L/s
Tick the 2 values you know, enter them, then click Solve
L/s
Pa/m
m/s
mm
mm × mm
Select 2 known values above
DuctSizer Pro — Results
Equivalent Diameter
mm
Recommended Round Duct
mm standard size
Flow Area
cm²
Fluid Velocity
m/s
Flow Rate
L/s
Flow Rate
m³/h
Reynolds Number
Friction Factor
Darcy-Weisbach
Velocity Pressure
Pa
Head Loss
Pa/m
Duct Size (if rect)
mm × mm
Flow Regime

Ventilation Sizing

ASHRAE 62.1-2022 Ventilation Rate Procedure

Ventilation Results — ASHRAE 62.1
Save to project room:
OA Flow Rate
L/s
OA Flow Rate
CFM
Air Changes / hr
ACH
Supply Air
m³/s
Per Person
L/s·person
Per m²
L/s·m²

Fan Power

Shaft and motor power from airflow and total pressure

Fan Results
Motor Power
kW
Motor Power
HP
Shaft Power
W
Overall Efficiency
%
Air Density
kg/m³
Airflow
CFM

Pipe Diameter

Velocity method with Darcy-Weisbach friction loss

Pipe Sizing Results
Calculated Diameter
Recommended DN
Velocity
m/s
Pressure Drop
Pa/m
Reynolds Number
Fluid

Pressure Drop

Darcy-Weisbach with Colebrook-White friction factor

Pressure Drop Results
Pressure Drop
Pa
Pressure Drop
kPa
Velocity
m/s
Reynolds Number
Friction Factor
Darcy
Pressure Drop
bar

Pump Power

Hydraulic and motor power sizing

Pump Results
Motor Power
kW
Motor Power
HP
Hydraulic Power
W
Shaft Power
W
Overall Efficiency
%
Flow Rate
L/s

Refrigerant Pipe Sizing

ACR copper pipe selection per ASHRAE Refrigeration Handbook

Refrigerant Pipe Results
Calculated OD
mm
Recommended ACR Size
Design Velocity
m/s
Mass Flow
kg/s

U-Value Calculator

Composite thermal transmittance per ISO 6946 — up to 5 layers

U-Value Results
W/m²K
R-Value
m²K/W
R-Value (Imperial)
ft²·hr·°F/BTU

Heat Exchanger Sizing

LMTD method — counterflow or parallel flow

Heat Exchanger Results
Heat Duty
kW
Required Area
LMTD
°C
Effectiveness
%
NTU
Heat Duty
BTU/hr

VENTUS C2020 Slot Grilles

Grille & spigot selection — University of Patras experimental data (Dr. Dionysis Margaris)

Enter total airflow and grille length. Returns velocity, throw, ΔP and noise for all C2020 sizes, plus spigot recommendations for every diameter.
C2020 Grille Results
GrilleFree Area (m²)Velocity (m/s)Throw (m)ΔP (Pa)Noise (dB)
Spigot Selection

VENTUS Linear, Slot & Camouflage

Linear C8-5 / C12-5, V-Cut C10-7, 2-Slot, 3-Slot, Camouflage — University of Patras data

Results scale linearly from reference data at 400 m³/h·m.
Grille Performance Results
Free Area
Velocity
m/s
Throw (to 0.5 m/s)
m
Pressure Drop
Pa
Noise
dB
Flow / metre
m³/h·m
Spigot Selection

Project Rooms

One room record feeds Cooling, Heating & Ventilation — save results back here instead of retyping

Saved Rooms
RoomArea (m²)Occ.CoolingHeatingVentilationActions

Load Schedule

Building-level rollup of every saved room, ready to export

Load Schedule
RoomSpace TypeArea (m²)Cooling (kW)Heating (kW)Ventilation (L/s)

Psychrometric Chart

Dry-bulb / humidity ratio plot at sea level — plot 2 state points and read the process line

Psychrometric Results
State 1 — Humidity Ratio
g/kg dry air
State 1 — Enthalpy
kJ/kg
State 2 — Humidity Ratio
g/kg dry air
State 2 — Enthalpy
kJ/kg
ΔEnthalpy (Total)
kJ/kg
Approx. Sensible Heat Ratio
Approximation at 101.325 kPa (sea level) using standard ASHRAE saturation-pressure correlations. SHR is estimated from ΔT vs ΔW proportion between the two points — for precise coil selection cross-check against a full psychrometric reference.

Takeoff / Bill of Quantities

Tally duct sheet metal, pipe length by size, and fittings for a quick material estimate

Duct Runs
ShapeSizeLength (m)Perimeter (m)Sheet Area (m²)
Pipe Runs
DN (mm)Total Length (m)
Fittings Count
Summary